Document network operations and WireGuard maintenance
This commit is contained in:
@@ -0,0 +1,129 @@
|
||||
# UniFi network configuration
|
||||
|
||||
## Controller
|
||||
|
||||
| Item | Value |
|
||||
|---|---|
|
||||
| Host | [ubnt](../hosts/ubnt.md) |
|
||||
| Address | `192.168.66.46` |
|
||||
| Deployment | Docker, `jacobalberty/unifi:v9.5.21`, host networking |
|
||||
| Inform endpoint | `http://192.168.66.46:9080/inform` |
|
||||
| MongoDB database / port | `ace` / `27117` |
|
||||
|
||||
Although `8080` is a common UniFi inform port, this controller uses `9080`.
|
||||
All AP adoption and recovery procedures must use the endpoint above.
|
||||
|
||||
## Inter-VLAN reachability
|
||||
|
||||
The AP management networks are routed by [gw](../hosts/gw.md),
|
||||
`192.168.66.254`. On 2026-08-05, a probe sourced from the LAN55 gateway
|
||||
(`192.168.55.254`) reached the controller (`192.168.66.46`) with 3/3 ICMP
|
||||
replies. The UAP-AC-Lite is online through the `:9080/inform` endpoint, which
|
||||
also confirms the required application path in practice.
|
||||
|
||||
`LAN_IN` contains explicit allow rules for `192.168.55.0/24 ↔
|
||||
192.168.66.0/24`, but the firewall set is currently inactive (not attached to
|
||||
an interface). Treat the networks as bidirectionally reachable by default;
|
||||
do not rely on those inactive rules as an access boundary. Recheck this after
|
||||
attaching any LAN firewall policy or changing VLAN routing.
|
||||
|
||||
To inspect device records from the controller host:
|
||||
|
||||
```bash
|
||||
docker exec -it unifi-controller bash
|
||||
mongo --port 27117
|
||||
```
|
||||
|
||||
```javascript
|
||||
use ace
|
||||
db.device.find(
|
||||
{ type: "uap" },
|
||||
{ name: 1, ip: 1, model: 1, inform_url: 1 }
|
||||
).pretty()
|
||||
```
|
||||
|
||||
## Managed access points
|
||||
|
||||
| Name | Model | Management IP | Firmware | Management network | Inform port |
|
||||
|---|---|---|---|---|---|
|
||||
| U6 Lite | U6 Lite (`UAL6`) | `192.168.66.6` | `6.7.54.15663` | LAN66 (`192.168.66.0/24`, gateway `192.168.66.254`) | `9080` |
|
||||
| UAP-AC-Lite | `U7LT` | `192.168.55.5` | `6.8.2.15592` | LAN55 (`192.168.55.0/24`, gateway `192.168.55.254`) | `9080` |
|
||||
|
||||
AP MAC addresses are recorded only where operationally needed: U6 Lite
|
||||
`78:45:58:4d:cc:30`; UAP-AC-Lite `f0:9f:c2:20:04:e9`.
|
||||
|
||||
## SSH administration
|
||||
|
||||
Adopted APs use the SSH account configured in the controller, rather than the
|
||||
factory `ubnt/ubnt` credential. The password is stored in the password manager
|
||||
and must not be added to this repository.
|
||||
|
||||
In UniFi Network `9.5.21`, configure it at:
|
||||
|
||||
```text
|
||||
Devices → Device Updates and Settings → Device SSH Settings
|
||||
→ Device SSH Authentication
|
||||
```
|
||||
|
||||
Use `ssh zhiqiangf@AP_IP` for the adopted-device account. Do not query or copy
|
||||
the controller's `mgmt` database setting into logs or documentation: it can
|
||||
contain the managed SSH password.
|
||||
|
||||
On 2026-08-06, key-only IPv4 SSH was verified for both managed APs using the
|
||||
`zhiqiangf` account. Verify future access without permitting password or
|
||||
keyboard-interactive fallback:
|
||||
|
||||
```bash
|
||||
ssh -4 -o BatchMode=yes -o PasswordAuthentication=no \
|
||||
-o KbdInteractiveAuthentication=no -o StrictHostKeyChecking=yes \
|
||||
zhiqiangf@192.168.66.6 'mca-cli-op info'
|
||||
ssh -4 -o BatchMode=yes -o PasswordAuthentication=no \
|
||||
-o KbdInteractiveAuthentication=no -o StrictHostKeyChecking=yes \
|
||||
zhiqiangf@192.168.55.5 'mca-cli-op info'
|
||||
```
|
||||
|
||||
Both devices reported `Connected` to
|
||||
`http://192.168.66.46:9080/inform` during that verification. The AP shell maps
|
||||
this management account to UID 0, so treat it as administrative access.
|
||||
|
||||
## Offline AP recovery
|
||||
|
||||
An AP can be reachable via ICMP and SSH but offline in the controller when its
|
||||
saved inform URL still points to port `8080`. This occurred for UAP-AC-Lite
|
||||
after its inform configuration had diverged from the controller endpoint.
|
||||
|
||||
From the AP, inspect the active endpoint and test controller reachability:
|
||||
|
||||
```bash
|
||||
info
|
||||
nc 192.168.66.46 9080
|
||||
```
|
||||
|
||||
The AP's BusyBox `nc` may not support `-zv`; use the plain `nc` invocation
|
||||
above when testing the TCP path.
|
||||
|
||||
If `info` reports `http://192.168.66.46:8080/inform` (or another obsolete
|
||||
endpoint), correct it. UniFi devices commonly require the command twice while
|
||||
adoption is completed:
|
||||
|
||||
```bash
|
||||
set-inform http://192.168.66.46:9080/inform
|
||||
set-inform http://192.168.66.46:9080/inform
|
||||
```
|
||||
|
||||
Verify that the AP changes to connected/online in the controller.
|
||||
|
||||
## Controller migration check
|
||||
|
||||
After a controller migration or restore, inspect stored device records for a
|
||||
stale default-port endpoint before treating an AP as faulty:
|
||||
|
||||
```javascript
|
||||
use ace
|
||||
db.device.find(
|
||||
{ inform_url: /8080/ },
|
||||
{ name: 1, ip: 1, inform_url: 1 }
|
||||
)
|
||||
```
|
||||
|
||||
Do not include credentials or controller database dumps in incident notes.
|
||||
Reference in New Issue